Why Acoustic Engineering Needs to Start Earlier in Industrial and Data Centre Projects

Why Acoustic Engineering Needs to Start Earlier in Industrial and Data Centre Projects

As industrial facilities and data centres become larger, more technically complex and increasingly integrated into their surrounding environments, acoustic considerations are a more important part of project planning than ever.

For Paul Mullen, Industrial Noise Control Manager at Ventac, one of the biggest challenges is helping clients understand that the noise performance of an individual piece of equipment does not necessarily tell the whole story.

A chiller, heat pump, generator or air-handling unit may have a specified sound power level or sound pressure level if it has been tested by the manufacturer under lab conditions, but once that equipment is installed in real-world situations, the surrounding environment can significantly affect how that noise propagates.

“The environment as a totality can cause problems,” Paul explains.

Equipment performance is only part of the picture

Equipment manufacturers increasingly provide acoustic performance data for their products, giving designers and clients a useful starting point when assessing potential noise impacts. However, Paul says the key consideration is what happens when that equipment is introduced into its actual environment.

“When that is dropped into the environment, that’s when it all changes,” he says.

“The location of the equipment, the surrounding buildings, nearby barriers and terrain and noise-sensitive receptors can all influence how sound travels, or propagation. A chiller located between two buildings, for example, might present very different acoustic challenges from the same unit positioned close to a residential boundary.”

Ventac has encountered situations where noise from an industrial source has been detected significant distances from the site itself. This highlights why assessing a project’s potential noise impact requires more than relying on the manufacturer’s stated noise levels. Proposed installation conditions and predicted noise levels at relevant receptors must also be considered to accurately evaluate the potential impact on the surrounding environment.

This is where acoustic modelling and specialist engineering become particularly important. By mapping a site’s existing and predicted noise environment, engineers can identify whether a proposed installation is likely to create an issue before equipment is switched on.

Importantly, the outcome is not always that additional acoustic treatment is required.

“We work to BS 4142, which is an assessment method to assess the impact of industrial and commercial sound on humans in nearby residential premises. We also work with relevant Irish guidance, including EPA NG4 and local authority planning and licencing requirements 

If you’re within compliance, we will tell you you’re compliant,” Paul says. “One of our core values is integrity. Rather than treating it as a commercial opportunity, our team will be honest with you so that you can have full confidence in Ventac.”

coustic enclosures

The cost of solving noise problems after installation

One of the recurring issues Paul encounters is when acoustic considerations are flagged after the equipment has been installed and a noise complaint has been received.

Once the equipment is operational, resolving the resulting noise issue can require substantial retrofit work, including structural steelwork, acoustic enclosures or barriers. For new developments, Paul believes there is a clear opportunity to avoid this situation altogether.

“I ask my customers, ‘Why would you bother waiting?’ Address the issue at hand first.”

Early consideration of acoustics can also prevent practical problems. If a project has already been designed around equipment with no space allocated for acoustic treatment, retrofitting an enclosure or barrier can require redesign, additional structural work and potentially significant cost.

Acoustic challenges across industrial sectors

In the pharmaceutical and food and beverage sectors, Paul is seeing a significant amount of equipment upgrading and expansion rather than entirely new-build facilities. These projects can introduce new noise sources in locations that create additional acoustic challenges. Equipment may be moved onto rooftops or installed closer to site boundaries, increasing the potential impact on surrounding areas.

“The noise source will spread – it can go to the top of the building or come out closer to the boundary,” Paul explains. “That’s where our remit and main task at hand is to basically to dampen the noise and make sure that they’re within compliance.”

Heat pumps are another increasingly relevant consideration. As heat pump technology becomes more widely adopted across factories, hotels and other facilities, Paul says there can be a disconnect between performance tested in isolation and in the conditions in which the equipment ultimately will operate.

Heat pumps, like other mechanical equipment, generate noise. Not all manufacturers use identical acoustic testing procedures or standards. If they don’t follow international standards, then the test data can be incorrect. In addition, the actual environment can affect how that noise propagates. This can sometimes lead to misunderstandings between equipment suppliers and clients and ultimately requires specialist acoustic engineering to resolve.

There is no one-size-fits-all acoustic solution

When asked about Ventac’s most popular acoustic products, Paul is reluctant to name a single solution because every project presents a different combination of noise sources, environmental conditions and operational requirements. However, there is one solution that frequently provides the starting point: the acoustic enclosure.

“If we can enclose that noise, we will,” he says.

An enclosure can completely encapsulate a noise source using acoustic panels, with the design adapted to accommodate requirements such as airflow, ventilation and equipment access. Where complete enclosure is not practical, an acoustic barrier can instead be used to interrupt the path between the noise source and the noise-sensitive area.

The solution may also incorporate acoustic treatments designed to reduce sound reflection from hard surfaces. In other applications, attenuators and plenums can be used to reduce noise while maintaining the airflow required by mechanical equipment.

The important point is that these solutions are not simply selected from a catalogue. They are engineered around the specific requirements of the equipment and its environment.

An industrial plant with multiple tall chimneys and complex structures stands bathed in the warm hues of a clear sunset sky, while advanced noise control solutions ensure a quieter environment.

Why early acoustic planning matters

For Paul, early engagement is one of the most important factors in successful noise control.

One example involved a pharmaceutical facility where mechanical equipment was being installed on a rooftop close to surrounding buildings. The project required a large acoustic screen to be installed around the mechanical equipment. By incorporating the screen into the project early, the acoustic treatment could be designed and installed as part of the construction sequence, rather than being retrofitted once the equipment was already operational.

This approach provided a number of practical benefits. The acoustic performance of the screen could be considered alongside the mechanical installation, while the finished screen also helped reduce the visual prominence of the rooftop equipment from the surrounding area.

For projects where mechanical equipment is being installed in dense urban environments, this type of early planning can be particularly valuable. Residential buildings, schools and other noise-sensitive receptors may be located close to industrial or commercial sites, making both the acoustic and visual impact of mechanical plant important considerations.

Ventac is applying the same principle to projects where equipment is being installed in constrained environments: understand the acoustic requirements first, map the site, design the appropriate solution and incorporate it into the construction sequence.

The role of acoustic modelling and technology

As technology develops, Paul sees significant potential for acoustic mapping and modelling to become an increasingly important part of project design. Being able to predict where noise will travel allows engineers to focus acoustic treatments where they will have the greatest effect.

“Once we know where the noise is drifting or travelling to, it makes our job a lot easier,” he says. “Now we can focus on a certain area.”

This is particularly valuable for large industrial installations and data centres, where multiple sources can operate simultaneously. Large chiller installations, for example, can involve numerous fans operating together, creating significant airborne noise. As the number of fans increases, tonal noise may become more prominent. Acoustic panels, attenuators and plenums can then be combined to reduce the impact of that noise while allowing the equipment to continue operating effectively.

Ventac’s own testing and engineering capabilities also play an important role. Solutions can be validated within the company’s acoustic laboratory, while site-specific conditions remain an important part of the overall assessment. As Paul explains, laboratory testing can establish how a product performs under controlled conditions, but understanding the environment in which the equipment will ultimately operate is essential.

If a noise-sensitive receptor is located some distance from a source, the acoustic impact may be very different from a situation where equipment is installed immediately adjacent to residential or other sensitive areas. So, this combination of laboratory testing, acoustic modelling and on-site assessment allows engineers to develop a more complete understanding of how a solution will perform in its intended environment.

Looking ahead

For Paul, one of the biggest challenges for acoustic engineering is keeping pace with rapidly developing equipment and technology. Manufacturers are continually introducing new products with increasingly specific acoustic performance claims. The challenge for acoustic engineers is ensuring that those figures are understood in the context of the actual project.

“Technology moves on at a rate of knots,” Paul says. “What we have to do is try to explain to our clients that the environment changes the noise.”

Air movement itself also generates noise, making airflow management a key consideration for large mechanical installations. In data centre applications, where substantial cooling infrastructure may operate continuously, managing airborne noise can become particularly important.

For Ventac, the answer is not necessarily a new product for every new piece of equipment. Instead, it is about understanding the acoustic behaviour of the equipment, the environment around it and how established acoustic technologies can be engineered together to solve the specific problem. Ventac’s engineers can combine multiple acoustic solutions depending on the requirements of the site, from enclosures and barriers to panels, attenuators and plenums.

That combination of acoustic knowledge, engineering expertise, modelling, testing and practical site experience allows acoustic considerations to move from being a reactive solution to an integral part of project design.

And perhaps the most important message from Paul’s experience is a simple one: don’t wait until the equipment is switched on to find out whether you have a noise problem.

Ventac provides CPD sessions to architects and engineering teams to highlight the importance of considering acoustics before equipment is selected and installed. Get in touch today to arrange yours: info@ventac.com